CSV

Here we intend to review the current state of the art of interactive data exploration techniques,

and to discover the maturity of the existing solutions. We look for solutions that satisfy three requirements:

access to raw data files, stored in a distributed environment, and with a reasonably low latency.

Method This work follows the well-defined guidelines for Systematic Mapping Studies, which is well-

suited for gathering and classifying available studies.

Categories:
191 Views

The experimental dataset involves the interval values for the bed slope (m/m) measured with a theodolite, the river flow rate (m^3/s), and the average surface velocity (m/s) from the Ter River (Spain).

Categories:
75 Views

This repository contains a data base of Cell Signal Quality samples obtained from 4 COTS cellphones. Data shows the dynamics of the cellular signal, and how these can be affected by the presence of human body nearby.

Categories:
441 Views

The frequency domain measurement of the scattering parameter, S21, of the wireless channel was carried out using the ZVB14 Vector Network Analyzer (VNA) from Rhode and Schwartz. The measurement system consists of the VNA, low loss RF cables, and omnidirectional antennas at the transmitter and receiver ends. The transmitter and receiver heights were fixed at 1.5 m. A program script was written for the VNA to measure 10 consecutive sweeps: each sweep contains 601 frequency sample points with spacing of 0.167 MHz to cover a 100 MHz band centered at 2.4 GHz.

Categories:
3408 Views

This is the maintenance service dataset collected in a smart water dispenser company in the year of 2017. 

 

 

Categories:
429 Views

The electronic system has been design to know the position human body. Of this way the system use a three axis accelerometer to detect five common positions (i) ventral decubitus, (ii) right lateral decubitus, (iii) left lateral decubitus, (iv) supine decubitus and (v) seated.  The sensor data was acquire with ten diferrents persons, their each positions was  how they felt confortable. The accelerometer acquire data from  3 axis possible (X,Y,Z)

Categories:
1435 Views

These datasets include the results from the comparison of different traffic-free path planning strategies presented in the work entitled "A primitive comparison for traffic-free path planning",  Antonio Artuñedo, Jorge Godoy, Jorge Villagra. https://doi.org/10.1109/ACCESS.2018.2839884

Categories:
156 Views

Understanding software is an inherent requirement for many maintenance and evolution tasks. Without a thorough understanding of the code, developers would not be able to fix bugs or add new features timely.  Measuring code understandability might be useful to guide developers in writing better code, and could also help in estimating the effort required to modify code components. Unfortunately, there are no metrics designed to assess the understandability of code snippets. 

Categories:
243 Views

This dataset contains user online reviews of two tourist places namely London' Parks and Art Museums.

London Parks Reviews

In this dataset, the top five most visited parks are selected, such as St. James' Park, Hyde Park, Regent's Park, Kensington Park and Greenwich Park. For each park, 600 reviews from Jan to Sep 2017 are present in CSV format.

London Art Museums

Categories:
2738 Views
Pressure position sensors and actuators are represented by red large and blue circles on the seating, respectively. Black circles display ultrasound sensors in the backrest, yellow arrows show output peripheral, and red arrows indicate peripheral input into the analog-digital converter.

S1= Preasure sensor, value 0-1023 decimal
S2= Preasure sensor, value 0-1023 decimal
S3= Preasure sensor, value 0-1023 decimal
S4= Ultrasonic sensor, value 0-15 cm
Categories:
1115 Views

Pages