Medical Imaging

Printed cirquit boards with charge coupled devices for on-chip lensless microscopes may be tested not in wetherometers and under solar simulators, but also under the experimental spectroreflectometric setup based on DATACOLOR 3890 with microphotometric and RS232-port-assisted data transfer into the PC memory.

Categories:
305 Views

Videomicroscopic Semi-Shadow Visualization of LoC-Si (Lab-on-a-Chip_[based_on]_Silicone) test structures from Institute of Molecular Electronics (D. Shevchenko; founder of Scientific and Production Association "Microbiotechniques" Ltd.) and Russian Academy of Sciences (INEPCP RAS; ICP RAS)

 

Vis. Tech.: MBS-10 Binocular Stereoscopic Microscope; Indirect Angular Illumination.

 

Found.: Initiative project (D. Shevchenko, O. Gradov; 2015-2016)

 

Fab.: JSC “Voskhod” KRLZ*

 

Categories:
199 Views

Modified characteriograph-assisted testings of spectrozonal analog lab-on-a-chip under laser beams

 

Acknowledgements:

  • “Development of the novel physical methods for complex biomedical diagnostics based on position-sensitive mapping with the angular resolution at the tissue and cellular levels using analytical labs-on-a-chip” (RFBR grant # 16-32-00914) [6 838,27 $ per year; 2016-2017];
  • “Lab-on-a-chip development for personalized diagnostics” (FASIE grant 0019125) [3 039,00 $ per year; 2016-2017].
Categories:
160 Views

LF-module-assisted analog lab-on-a-chip measurements with R- (650 nm), G- (532 nm), B- (405 nm) laser sources

 

00:59 - Wavelenth: 650 nm (laser diode);

01:25 - Wavelenth: 405 nm (DPSSL);

01:43 - Wavelenth: 532 nm (DPSSSL);

 

Acknowledgements:

Categories:
130 Views

Testings of spectrozonal analog lab-on-a-chip with angle-sensitive pixels (ASP) using diode laser sources in combined nanosecond reflectometric and stroboscopic oscilloscopic measurements.

 

FILE 1: Combined nanosecond reflectometric and stroboscopic oscilloscopic analysis for RF lab-on-a-chip.mp4

00:15 - Wavelength: 405 nm (DPSS);

00:57 - Wavelength: 650 nm (laser diode source);

 

FILE 2: Analog angle-sensitive pixel lab-on-a-chip testing using nanosecond stroboscopic oscilloscope.mp4

00:20 - Zero Point Calibration (ZPC);

Categories:
159 Views

In this study, adaptive hybrid (AH) scheme is proposed to enhance the measurement accuracy of conventional CD method to acquire the 2-dimensional velocity field of blood flows. It can offer the assistance of the velocity field information measured preliminarily using ultrasound speckle image velocimetry (SIV) technique. Consequently, erroneous vectors in the CD results were replaced with the SIV results. The performance of the proposed AH method was validated by varying flow rate and insonation angle. We compared the AH method with the CD and SIV methods in an agarose vessel model.

Categories:
260 Views

Background: Retinopathy of prematurity (ROP) is one of the main causes of childhood blindness. However, insufficient ophthalmologists are qualified for ROP screening.
Objective: To evaluate the performance of a deep neural network (DNN) for automated screening of ROP.

Categories:
2124 Views

A sample of synthetic noise-free reference image created by combining multiple instances of structurally preserved cilia cross-sections. The author has removed the dataset, the interested users can contact the author via email: amitsuveer@gmail.com 

Categories:
223 Views

This dataset is for the paper titled: Segmentation of Cervical Cell Images based on Generative Adversarial Networks. The dataset is used to train and test the Cell-GAN, a generative adversarial network. After training, the Cell-GAN is able to generate a complete single-cell image which has the similar contour to the cell to be segmented.

Categories:
1186 Views

For the development and evaluation of organ localization methods, we build a set of annotations of organ bounding boxes based on the MICCAI Liver Tumor Segmentation (LiTS) challenge dataset. Bounding boxes of 11 body organs are included:  heart (53/28), left lung (52/21), right lung (52/21), liver (131/70), spleen (131/70), pancreas (131/70), left kidney (129/70), right kidney (131/69), bladder (109/67), left femoral head (109/66) and right femoral head (105/66). The number in the parentheses indicates the number of the organs annotated in training and testing sets.

Categories:
3720 Views

Pages